Test Center

Test Center Building

Test Center Building

Total Closed Area: 5200 M²

Test Facility Hardware Features

4 x Engine Test Chambers

2 x Transmission Test Chambers

2 x Power Pack Test Chambers

1 x Tilt Table Test Chamber

Stock Area, Office and Social Areas

Special Test Units and Infrastructure

Torque Converter, Hydrostatic Pump, Oil and Water Pumps, Valve Block, and other Subsystem Test Rigs.

Power Group Test Rooms

Power Group Test Rooms have AC electric motor dynamometer and configurable test automation system and all necessary test, measurement and conditioning systems for development and endurance tests of power groups up to 1800 HP. The Power Group Test Rooms are also equipped with flywheel sets for inertia simulation of heavy-duty vehicles.

Engine Test Rooms

Engine Test Rooms, which have test automation systems that can be configured with AC electric motor dynamometer and hydraulic brake dynamometer, have all necessary test, measurement and conditioning systems for development and endurance tests of internal combustion engines up to 1800 HP.

Transmission Test Rooms

Transmission Test Chambers, which have a configurable test automation system with brake and drive AC electric motor dynamometers, have all necessary test, measurement and conditioning systems for the development and endurance tests of transmissions up to 1800 HP. The test rooms also allow for flexible AC electric motor dynamometer installation configurations and testing of power packs, motors and other power transmission systems.

Tilt Table Test Chamber

The Tilt Table Test Chamber has hydraulic cylinders that allow testing of the engine, transmission and power pack under all possible road and terrain slope conditions, and a table that can tilt ± 45° in the inner and outer axis.

BMC Power